DMP 36” 7.2 Roofing and Wall Panel

Panel Information
  • Panel Type: Screwdown (Exposed Fasteners)
  • Panel Coverage: 36”
  • Rib Height:1 ½”
  • Rib Spacing: 7.2” on Center
  • Available Gauges: 26ga or 24ga Steel
  • Weight: 3.0 lb/lnft (26 gauge) or 4.0 lb/lnft (24 gauge)
  • Minimum Slope: 1/12
  • Substrate: Solid Deck or Open Frame
Fastener Guide:
  • #10 Woodfast screws are designed for use with dimensional lumber
  • #14 Wafer screws are designed for use with plywood sheeting, OSB, and wafer wood (7/16” minimum thickness)
  • #12 Tek Screws are designed to be used with structural steel up to 3/16” thickness
Roof Application:
  • Screws are to be installed no more than 3’6” up the panel. Pre-drilling is recommended to ensure water tightness. It is recommended to use Bead Seal between every panel at the side lap with Stitched Screws installed every 1’0” up the panel. Any slope below a 4:12 must use Bead Seal and Stitch Screws.
Wall Application:
  • Screws are to be installed no more than 3’6” up the panel. Pre-drilling is recommended to ensure water tightness.